Permitrust Premium Permit Intelligence
PT-AUS-DECK-4906-0826 · Version 2.0
PROJECT ID PT-AUS-DECK-4906-0826
DIY Permit Research

Deck Permit
Intelligence Report

Property-specific permit research for 4906 Lynnwood St, Austin, Texas 78756 . This report evaluates the proposed residential deck against Austin's permitting, zoning, setback, structural, inspection and development requirements.

PROJECT ID PT-AUS-DECK-4906-0826
Prepared For Mark Domingos
Property 4906 Lynnwood St
Research Date August 25, 2026
Product DIY Report
Executive Decision HIGH RESEARCH CONFIDENCE

Permit-required
project path.

The proposed deck should not rely on Austin's permit exemption.

46
Permit Readiness
STATUS
NOT READY
Exemption fails height + attachment tests
Exact deck placement not yet demonstrated
Parcel floodplain result still outstanding
Easement / tree review not fully resolved
01 · Executive Decision

The answer in one minute

RESEARCHED
🔴 CAN THE CUSTOMER BUILD THIS DECK WITHOUT A PERMIT?

No. Based on the stated project inputs, the proposed 192-square-foot deck should use Austin's residential Pool/Uncovered Deck permit pathway. The project is approximately 48 inches above grade and attached to the dwelling. Those facts defeat key published exemption conditions.

🏛
Building Permit REQUIRED PATH
Project does not satisfy the published deck exemption conditions.
Deck Exemption DOES NOT QUALIFY
Attached and approximately 48 inches above grade.
Zoning SF-3
Property-specific City record.
Setbacks 5 FT / 15 FT
5-ft interior side and 15-ft through-lot rear framework.
Parcel 6,591 SF
Secondary property record; TCAD should remain authoritative.
Floodplain NOT RETRIEVED
Parcel-level FloodPro result not obtained.
Structural REVIEW REQUIRED
Attached ~4-ft deck requires detailed structural treatment.
!
Construction Ready NO
Multiple application-stage blockers remain.
WHAT IS STOPPING CONSTRUCTION READINESS?

The report has identified the zoning, property-specific setback framework and permit pathway. The remaining blockers are primarily site-placement evidence, parcel floodplain evidence, easement review, tree/environmental review where applicable, and the final application/structural package.

02 · Property Intelligence

What we know about this property

PROPERTY-SPECIFIC
PARCEL / APN

0225030308

Secondary property record cross-check. Official TCAD Property Search should remain the controlling parcel source.

SECONDARY SOURCE
LOT AREA

6,591 sq. ft.

Approximately 0.15 acre according to the secondary property record.

EXISTING BUILDING

1,424 sq. ft.

Secondary property record identifies approximately 1,424 sq. ft. of building area.

YEAR BUILT

1937

Secondary property record.

LEGAL DESCRIPTION

LOT 3

LOT 3 RESUB BLK 4AND5 ROSEDOWN

CITY RECORD
PROPERTY TYPE

Residential

The property-specific City record is an SF-3 single-family residential property.

PARCEL DATA WARNING

The parcel number and appraisal-style property measurements above are presented as a secondary-source cross-check. Permitrust should retrieve the live official TCAD Property Search record before issuing a production report.

03 · Project Profile

The exact project being tested

PROJECT INPUTS
DIMENSIONS

12 ft × 16 ft

Customer/project input.

AREA

192 sq. ft.

12 × 16 = 192 sq. ft.

HEIGHT

Approximately 48 inches

Critical exemption input.

ATTACHMENT

Attached to dwelling

Critical exemption input.

COVER

Uncovered

Proposed scope.

USE

Residential

Residential.

04 · Permit Determination

Correct application pathway

VERIFIED
APPLICATION

Pool / Uncovered Deck

Austin's Residential Plan Review page currently lists a Pool/Uncovered Deck web form for pool or uncovered wooden deck construction, replacement or repair on a residential lot.

REPORT DECISION

Permit-required path

The assumed project does not qualify for the published exemption.

SUBMISSION ROUTE

Use the City of Austin Residential Plan Review process and the current Pool/Uncovered Deck application. The City's current plan-review page states that Swimming Pool/Uncovered Deck projects have a 5-business-day review time.

05 · Exemption Analysis

Requirement vs project

DECISIVE
Condition
Austin requirement
Proposed project
Result
Maximum deck area
200 sq. ft. or less
192 sq. ft.
PASS
Height above grade
30 inches or less
Approximately 48 inches
FAIL
Attachment
Detached from dwelling / townhouse
Attached
FAIL
Dwelling egress
Must not provide dwelling egress
Exterior stairs assumed
PROJECT REVIEW
Flood hazard area
Must be outside applicable flood hazard area
Parcel result unavailable
NOT RETRIEVED
FINAL EXEMPTION RESULT: DOES NOT QUALIFY

The project fails the height and attachment conditions before floodplain status even becomes necessary to make the permit determination.

06 · Exact Site Development

Does the 12 × 16 deck actually fit?

PLACEMENT NOT CERTIFIED
Item Requirement Project / Evidence Finding
Lot area Property-specific 6,591 sq. ft. IDENTIFIED
Proposed deck area Project input 192 sq. ft. 2.91% OF LOT AREA
Interior side setback 5 ft Exact deck placement not supplied CANNOT CERTIFY FIT
Through-lot rear setback 15 ft Exact deck placement not supplied CANNOT CERTIFY FIT
Building coverage Property-specific calculation Existing footprint not independently established NOT DETERMINABLE
Impervious cover Property-specific calculation Existing impervious surface inventory unavailable NOT DETERMINABLE
FAR If applicable No project-specific FAR calculation established NOT DETERMINABLE
IMPORTANT: SETBACKS ARE KNOWN — DECK FIT IS NOT

The report knows the property-specific 5-ft side and 15-ft through-lot rear setback framework. It does not have a surveyed site plan showing where the proposed 12 × 16 ft deck will sit. Therefore Permitrust should not falsely report "PASS" or "FAIL" for exact deck placement.

07 · Zoning & Setbacks

Property-specific zoning controls

CITY RECORD
ZONING

SF-3

Single-Family Residence.

INTERIOR SIDE

5 ft

Required setback identified in the property-specific Board of Adjustment record.

THROUGH-LOT REAR

15 ft

Required rear-yard framework identified in the property-specific record.

CODE SECTIONS IDENTIFIED IN THE PROPERTY CASE

The 2024 Board of Adjustment case references LDC §25-2-492 for site development regulations and LDC §25-2-515 for rear yards of through lots.

08 · Easements & Right-of-Way

Hidden site constraints

RECORD SEARCH INCOMPLETE
RECORDED EASEMENTS

Not established

No deed/plat easement determination was retrieved from the accessible sources used for this report.

RIGHT-OF-WAY

No conflict established

No property-specific ROW conflict was identified in the reviewed material, but this is not a title/plat certification.

UTILITY

Austin Energy reviewed prior case

Austin Energy did not oppose the 2024 variance request subject to its clearance and safety criteria.

REQUIRED ACTION

Review recorded plat/deed

Final deck placement should not be certified until easement information is available.

09 · Floodplain / Trees

Environmental constraints

TWO PROPERTY CHECKS REMAIN
FLOODPLAIN

Parcel result not retrieved

Austin's FloodPro system is the official municipal route for property-level floodplain mapping. The report does not claim a flood-zone result without the actual parcel map.

Open Austin FloodPro ↗
TREES

Property-specific tree result not retrieved

Austin requires tree review where regulated trees or critical-root-zone impacts are involved. Protected trees on residential property generally begin at 19 inches diameter.

View Austin Tree Rules ↗
WHY THESE ARE NOT LABELED "PASS"

A premium permit report should not convert "search did not return a result" into "no issue." The correct evidence status is Unable to Verify until the actual property-level source is retrieved.

10 · Property History

Prior municipal activity

SIGNIFICANT RECORD FOUND
BOARD OF ADJUSTMENT

C15-2024-0047

Property-specific variance case for 4906 Lynnwood St.

DECISION

Granted

Board decision dated December 9, 2024.

PRIOR VARIANCE

5 ft → 2 ft 5 in

Requested reduction to the interior side-yard setback for the prior project.

PRIOR REAR VARIANCE

15 ft → 3 ft

Requested reduction to the through-lot rear setback for the prior project.

IMPORTANT

The existence of a prior variance does not automatically grant the proposed deck the same relief. The prior variance related to a different scope: conversion/change of use involving an existing detached garage.

11 · Code Analysis

Rule → trigger → conclusion

CODE-BASED
Issue Rule / Source Project Trigger Conclusion
Permit exemption Austin residential exemption framework Attached + approximately 48" FAIL
Side setback LDC §25-2-492 5-ft required framework SITE PLAN REQUIRED
Through-lot rear LDC §25-2-515 15-ft framework SITE PLAN REQUIRED
Residential code 2024 IRC + Austin local amendments New residential deck APPLIES
Tree ordinance Austin Tree Ordinance / ECM Regulated trees / CRZ if present TREE CHECK
12 · Structural Requirements

What the structural package must address

DESIGN STAGE
FOUNDATION

Footings / Piers

Final support system must be shown.

FRAMING

Posts / Beams / Joists

Framing arrangement must match approved plans.

ATTACHMENT

Ledger / Connections

Critical because the project is assumed attached.

STAIRS

Stair Geometry

Final stair design must comply with applicable code.

GUARDS

Guards / Handrails

Required based on final deck height and configuration.

ENGINEERING

Height-sensitive review

The assumed approximately 4-ft-high attached deck deserves detailed structural documentation.

FOUNDATION INSPECTION EXCEPTION IS NOT A FREE PASS

Austin's foundation inspection materials identify a narrow exception for an uncovered deck that is independent of another structure, no more than 4 ft above the relevant grade condition, less than 200 sq. ft., and built using prescriptive residential-code methods. This project is assumed attached, so Permitrust should not automatically apply that independent-deck exception.

13 · Submission Package

What the customer should prepare

APPLICATION PATH IDENTIFIED
Document Primary responsibility Why it matters
Residential Pool / Uncovered Deck Application Homeowner / Contractor Primary application pathway for the proposed project.
Site / Plot Plan Designer / Contractor / Surveyor as appropriate Shows property boundaries, structures, proposed deck and required setbacks.
Deck Plan Designer / Contractor Shows exact dimensions and configuration.
Elevations Designer / Contractor Shows grade relationship and deck height.
Foundation / Footing Details Designer / Engineer Documents support system.
Framing Plan Designer / Engineer Documents beams, joists and posts.
Ledger / Connection Details Designer / Engineer Important because the project is assumed attached.
Stair / Guard Details Designer / Contractor Documents safety components and geometry.
Tree Documentation Applicant / Arborist if applicable Required if regulated trees or critical-root-zone impacts are involved.
Floodplain Documentation Applicant / Designer Required to resolve the current parcel-level floodplain gap.
FINAL PACKAGE CHECK

The application package should be internally consistent: site plan dimensions, deck dimensions, elevations, structural details and application information should all describe the same project.

14 · Cost Exposure

Municipal fee planning

BUDGETARY
Fee component Amount Status Explanation
Residential plan-review base component $179.30 Published schedule component Addition/remodel review base; exact fee treatment depends on application scope.
Residential application processing $106.72 Published schedule component Residential plan-review application processing fee.
Building permit base component $289.53 Planning component Base building permit component; not a complete deck permit quote.
Standalone inspection component $67.10 Planning component First standalone-project inspection component reported in current fee data.
Planning-level subtotal $642.65 DERIVED Not a City quote. Additional fees or different application treatment may apply.
Reinspection $76.23 Published Applies when a reinspection is required.
Major plan revision / resubmittal $532.52 Published Potential additional exposure if significant corrections are required.
Minor plan revision $84.15 Published Potential additional correction fee.
PLANNING SUBTOTAL: $642.65

This is a Permitrust planning calculation based on published/current component data. It is not a City quote. The final amount can change based on the City's application classification, project scope, inspection requirements, additional review disciplines, revisions, tree/flood/erosion review and other applicable charges.

Austin's FY2025–26 fee schedule is the controlling source for municipal fees. View official fee schedule ↗

15 · Inspection Requirements

From permit to completion

CITY PROCESS
01

Foundation / Footing EXPECTED

Foundation and footing work must be inspected under the applicable residential inspection framework. The City provides a foundation inspection checklist.

02

Framing EXPECTED

Structural framing should be inspected before work is concealed, consistent with the approved plans and applicable inspection requirements.

03

Structural / Connection Review PROJECT-SPECIFIC

Ledger, posts, beams, joists, guards, stairs and connections must match the approved design.

04

Final Building Inspection REQUIRED

The responsible contractor is responsible for scheduling required inspections, including the final building inspection.

05

Permit Closure REQUIRED

The project should not be treated as complete until required inspections have passed and the permit is properly closed.

INSPECTION RULE

The exact inspection sequence assigned to the permit controls. The report should never promise a specific inspection order if the issued permit assigns something different.

16 · Approval Timeline

What the customer should expect

5 BUSINESS DAYS
CITY REVIEW

5 business days

Current Austin Residential Plan Review information lists 5 business days for Swimming Pool/Uncovered Deck projects.

CORRECTIONS

Additional time possible

Corrections or resubmittals can extend the actual project timeline beyond the published review target.

REALISTIC PLANNING

Review + corrections + issuance

Permitrust should not market 5 business days as a guaranteed permit-issuance date.

17 · Contractor Requirements

Who can pull and activate the permit?

VERIFIED
GENERAL CONTRACTOR

Texas does not require a state GC license

Austin states that anyone can be a general contractor in Texas, including a homeowner, although Austin registration requirements still apply.

AUSTIN REGISTRATION

Required before activation

General contractors, trade contractors and homeowners acting as contractors must register with Austin's Building and Trade Contractor Services before obtaining/activating applicable permits.

AB+C

Portal account

The general contractor assigned to the building permit must have an Austin Build + Connect account.

RESPONSIBILITY

Inspections + activation

The registered GC is responsible for permit activation, payment, approved work and scheduling required inspections.

18 · Office to Contact

Where the customer goes for help

Official Municipal Contact

Austin Development Services

📍
Physical Address Permitting and Development Center (PDC) 6310 Wilhelmina Delco Dr. Austin, TX 78752
Development Services 512-978-4000 Austin 3-1-1
Email DSDHelp@austintexas.gov
🕐
PDC Hours Monday–Friday: 7:45 AM–4:45 PM Walk-in services: Monday–Friday, 8 AM–4 PM
📍 Open Office in Google Maps ↗
BEST CONTACT FOR THIS REPORT

For questions about the residential deck permit pathway, zoning, application status or development requirements, the customer should contact Austin Development Services rather than relying on a generic City department.

19 · Risk Assessment

What can still stop this project?

RISK MAP
Deck exemption fails HIGH

The assumed deck is attached and approximately 48 inches high.

Exact placement not proven HIGH

The report has the property-specific setbacks but not a surveyed deck placement.

Floodplain result missing HIGH

A parcel-level FloodPro determination was not retrieved.

Easement status unresolved HIGH

No recorded easement/plat determination was available in the reviewed sources.

Tree review may apply MEDIUM

Austin requires tree review where regulated trees or critical-root-zone impacts are involved.

Fee exposure MEDIUM

Exact fees depend on the final application and project scope.

Permit pathway LOW

Austin currently provides a specific Pool/Uncovered Deck residential pathway.

Review target LOW

Austin currently lists 5 business days for Swimming Pool/Uncovered Deck residential plan review.

20 · Construction Readiness

Is the project ready to build?

46 / 100
46 NOT READY
VERIFIED

Zoning

SF-3 confirmed.

VERIFIED

Permit Path

Pool / Uncovered Deck.

BLOCKER

Exact Placement

Site plan not yet demonstrated.

BLOCKER

Floodplain

Parcel result missing.

BLOCKER

Easements

Deed/plat evidence missing.

BLOCKER

Final Plans

Structural package not complete.

WHY 46 / 100?

The score is a Permitrust readiness metric — not a municipal approval score. The project has a clear permit path and verified zoning, but several evidence and submission blockers remain.

21 · Action Plan

Exact next steps

ACTIONABLE
01

Confirm the parcel record

Use the official TCAD property search to confirm parcel number, lot information and current appraisal data.

02

Obtain the actual site plan

Plot the 12 × 16 ft deck against property boundaries and the 5-ft / 15-ft setback framework.

03

Resolve easements

Review the recorded plat/deed and any utility or drainage easements before finalizing deck location.

04

Run the parcel floodplain check

Obtain and retain the actual Austin FloodPro parcel result.

05

Check regulated trees

Identify protected/heritage trees and critical-root-zone conflicts before construction.

06

Finalize structural design

Prepare footing, post, beam, joist, ledger, stair, guard and connection details.

07

Prepare the application package

Complete the current Pool/Uncovered Deck residential application and supporting drawings.

08

Register the responsible contractor

The responsible general contractor/homeowner acting as contractor must satisfy Austin registration requirements before permit activation.

09

Submit through Austin

Use the applicable Austin Development Services residential web-form / AB+C pathway.

10

Complete inspections

Schedule and pass the inspections assigned to the permit.

11

Close the permit

Do not treat the project as complete until required inspections have passed and the permit is closed.

Responsibility Matrix

Who does what?

Task Homeowner Contractor Designer / Engineer City
Confirm property parcel data YES HELP HELP SOURCE
Final site plan PROVIDE YES YES REVIEW
Structural drawings HELP YES REVIEW
Permit application YES YES HELP PROCESS
Permit payment YES YES RECEIVE
Inspections COORDINATE YES IF REQUIRED PERFORM
Final approval / closure YES IF REQUIRED APPROVE
22 · Evidence Trail

Official sources & research references

SOURCE LIBRARY

Permitrust separates official municipal records, property-specific records, secondary cross-checks, project inputs and unresolved research items.

Austin Development Services — Contact
City of Austin · Primary
Office address, phone and DSD contact.
Open Source ↗
Austin Development Services — Residential Plan Review
City of Austin · Primary
Permit pathway, code framework and current review times.
Open Source ↗
Pool / Uncovered Deck Application
City of Austin · Primary
Current residential application.
Open Source ↗
Interactive Pool / Uncovered Deck Guide
City of Austin · Primary
Application instructions.
Open Source ↗
Work Exempt from Building Permits
City of Austin · Primary
Deck exemption rules.
Open Source ↗
FY 2025–26 Development Services Fees
City of Austin · Primary
Current fee schedule.
Open Source ↗
Contractor Registration
City of Austin · Primary
Contractor registration and responsibilities.
Open Source ↗
Homeowner Permit / Permit Expiration
City of Austin · Primary
Permit expiration and contractor responsibilities.
Open Source ↗
Building Inspections
City of Austin · Primary
Inspection process and residential inspection resources.
Open Source ↗
Trees on Residential Property
City of Austin · Primary
Protected trees and tree review.
Open Source ↗
Property Profile
City of Austin · Primary
Official property-data lookup.
Open Source ↗
TCAD Property Search
Travis Central Appraisal District · Primary
Parcel/account verification.
Open Source ↗
Board of Adjustment Case C15-2024-0047
City of Austin · Property-specific
SF-3 zoning, through-lot condition and setbacks.
Open Source ↗
Board of Adjustment Advance Packet
City of Austin · Property-specific
Property description, zoning and Austin Energy review.
Open Source ↗
Floodplain Maps / FloodPro
City of Austin · Primary
Official parcel floodplain lookup.
Open Source ↗
Secondary Property Record
Property-data source · Secondary
Parcel number, lot area, building area and year-built cross-check.
Open Source ↗
23 · Final Decision

Do not build this deck yet. The correct path is to complete the permit package first.

The proposed 192-square-foot deck does not qualify for Austin's residential deck exemption because the stated design is attached and approximately 48 inches above grade.

The property-specific City record identifies the property as SF-3, identifies it as a through lot, and establishes a 5-ft interior side-yard and 15-ft through-lot rear-yard framework.

The project still requires a property-level site placement check, floodplain result, easement review and any applicable tree/environmental review before Permitrust should call the project construction-ready.

Austin currently provides a Pool/Uncovered Deck residential permit pathway and lists a 5-business-day plan-review target for this project category.

Current construction readiness: 46 / 100 — NOT READY.

Your premium permit report is ready.

Print the complete report or save it as a PDF (portrait). The Permitrust website header and footer will not print.

Evidence & Scope: Permitrust organizes available municipal records, property information, project inputs, applicable regulations, and supporting sources into a structured permit-research report. Findings are identified by their evidence level, including verified records, secondary-source information, project-provided details, derived calculations, and items that could not be confirmed from the sources reviewed. This report is intended to support permit planning and application preparation. It does not replace official municipal records, surveys, engineering plans, legal or title review, or decisions made by the applicable permitting authority. Requirements and project conditions may change, and the permitting authority retains responsibility for reviewing and approving the final application.

Demo Report Notice: This report is provided for educational and demonstration purposes only and is presented solely as an example of the Permitrust permit-research experience. The name, property address, project details, and any other personal or property-related information displayed in this demo are fictional or used solely for demonstration purposes and are not intended to represent an actual customer or real permit application. Because this is a demonstration report, its findings, examples, calculations, and conclusions should not be used to make construction, permitting, financial, legal, or property-related decisions. For an actual project, use a project-specific Permitrust report and confirm applicable requirements with the relevant permitting authority and qualified professionals.